16 optocoupler/16 relay hybrid module for loads up to 3A
404,11 € Prices plus statutory VAT | plus shipping and handling
Availability:
In stock!
Delivery in 2-3 working days
16 optocoupler/16 relay hybrid module for loads up to 3A
Our yamutec® USB HYBRID 16_3A module is designed for high loads and can reliably switch load circuits with up to 3A. The USB modules are equipped with 16 optocoupler inputs and 16 relay outputs. This way you can capture signals safely and convert them directly into control commands.
The yamutec® USB hybrid module has 16 PCN series print relays for the outputs that can switch loads of 3A or 90W. We work with that MULTI CONNECTION SYSTEM, which guarantees 100 percent protection against mis-mating and is equipped with practical ejectors. You can also code the relays by cutting off the coding lugs.
For the 16 entrances of our yamutec® Modules we use optocouplers. These optoelectronic components enable galvanic isolation during signal acquisition. You can use the optocoupler inputs for a voltage range of 3V to 30V. All yamutec® hybrid modules were developed for industrial use and are therefore subject to the EMC and RoHS.
The advantages of the yamutec® USB HYBRID 16_3A module at a glance:
- High switching capacities at the inputs are possible
- Fast input pulses over a long period of time are not a problem
- long service life of the optocouplers
- insensitive to shock and vibration
- low switching losses at the outputs
- Short-term overloads are not a problem
- reliable disconnection and switching
Are you looking for a hybrid module for smaller load circuits? Then just take a look at ours USB Hybrid 16 module.
Technical data
USB INTERFACE | |
---|---|
supply voltage | External 7V to 24V DC (via two-pole pluggable screw terminal) USB power supply (can be changed via jumper) |
interface | USB 2.0 |
control LEDs | Internal 5V supply voltage interface activity Timout shutdown (only for outputs) I/O activity Error message |
EXITS | |
relay | 16 relay outputs, Galvanically isolated via relays Max. switching voltage: 30V AC / 30V DC Max. switching current: 3A AC /3A DC Max. transport current: 3A AC / 3A DC Max. switching power: 90W Switching time: < 1 ms |
Timeout function | Selectable timeout protection when the module is unreachable |
ENTRANCES | |
optocoupler | 16 optocoupler inputs 3V – 30V AC/DC signal voltage Isolation voltage: 2.5KV AC for 1 minute Maximum input current: 10mA |
CONNECTOR | |
Characteristics | 2 ROW MULTI CONNECTION SYSTEM Universal connection for all types of conductors Locking the plug connection Codeable and 100 % protected against mismating by cutting off the coding lugs |
Connection data | Solid conductor 0.08 … 1.5 mm² / 28 … 16 AWG Fine-wire conductor 0.08 … 1.5 mm² / 28 … 16 AWG Fine-wire conductor; with wire end sleeve with plastic collar 0.25 ... 1 mm² Fine-wire conductor; with wire end sleeve without plastic collar 0.25 ... 1 mm² Stripping length 6 … 7 mm / 0.24 … 0.28 inch |
Recommended accessories |
A strain relief plate that can be mounted in the middle between the conductor entries facilitates the plugging and unplugging process and allows easy access to the actuation openings even when wired |
DIMENSION | |
Dimensions Weight |
147.5mm x 105mm x 74.5mm (L x W x H) 320g |
Downloads
MANUAL | |
---|---|
Instructions | German English |
SOFTWARE | |
---|---|
sample software | VB.net, C# and Python / Requirement: Windows 7/8/10 or Linux without installation |